Cardiac Science Powerheart G5 XELAED003C Original Paediatric Defib Pads
£104.07 £124.88 Inc Tax
Description
Euro Energy Part Number: 06653
Cardiac Science Powerheart G5 XELAED003C Original Paediatric Defib Pads
Cardiac Science Original Part Number: XELAED003C Original Electrodes
For Use with the Cardiac Science Powerheart G5 Defibrillator
These are genuine original CS Powerheart G5 Paediatric Defib Pads, part number XELAED003C .
Featuring fully automatic operation, the Powerheart G5 defibrillator recognises when a shock is required and delivers this without the need of manual input. Powered by the G5 Original battery number XBTAED001A, Euro Energy part number 02284, the Cardiac Science G5 defibrillator provides easy to follow, clear voice and text prompts throughout treatment, designed to help keep the responder calm while operating the defibrillator. Please note! These pads have a shelf life of 21 – 24 months and must be replaced upon expiry to ensure the ongoing functionality of the Powerheart G5 defibrillator.
Product Features:
- Fully automatic operation – automatically delivers a shock, if needed
- Daily, weekly and monthly automatic self tests performed by the unit, including testing of the XBTAED001A battery/ 02284 Lithium non rechargeable battery
- Energy levels are increased should the initial lower dose shock be unsuccessful
- Robust IP55 rated design for high resistance against dust and moisture
- Provides LED indication for visual assurance that the defibrillator is fully functional
- Battery status indicator shows the remaining XBTAED001A battery capacity
- Non-polarized (identical) adult pads help to save time in an emergency, Euro Energy part number 06582, Cardiac Science Powerheart G5 Adult Defib Pads, XELAED001B Original Electrodes
- Stores usage information that can be transferred to a computer for analysis: USB port
- Can be used on young patients with the infant/child pads, Euro Energy part number 06653, Cardiac Science Powerheart G5 Paediatric Defib Pads, XELAED003C Original Electrodes
- Typical time taken for initial analysis and time to charge: 15 seconds
For further information on this or other Cardiac Science/Zoll medical accessories, or to discuss our range of Original Manufacturer medical batteries & Compatible medical batteries, Original Manufacturer medical accessories and general purpose Sealed Lead Acid/VRLA batteries contact our friendly & knowledgeable UK Customer Services team on Leicester 0116 2340567 or email info@euroenergy.co.uk